Kondensatur tal-Enerġija b'Vultaġġ Għoli BAM
Applikazzjoni u Standards:
Il-kapaċitatur ta 'vultaġġ għoli jintuża prinċipalment fis-sistema tal-Enerġija AC b'50Hz biex itejjeb il-fattur tal-qawwa. Il-prestazzjoni tikkonforma ma 'GB 3083.2-89 《High voltage shunt capacitor》u IEC 60871-1987.
GB/T11024-2010 Standard nazzjonali 《Vultaġġ nominali 1kV jew ogħla shunt capacitors għal sistemi ta' enerġija AC
JB/7112-2000 Standard tal-Industrija tal-Makkinarju 《Kondensatur Shunt HV immuntat
DL/T628-1997 Standard tal-Industrija tal-Enerġija Elettrika 《Rekwiżit Tekniku tal-Ordni tal-Kondenser tax-Xant HV immuntat
Kundizzjonijiet tal-Użu:
1.Altitudni: inqas minn 1000m; Temperatura ambjentali: -40℃ ~ +40℃。
2.L-ebda vibrazzjoni mekkanika vjolenti, l-ebda gass u fwar ta 'ħsara, l-ebda trab elettriku, u splussiv, u splussiv fil-post.
3.Vultaġġ ta 'tħaddim kontinwu: 1.00 Un, massimu fit-tul, Vultaġġ żejjed: inqas.1 Un.
4.Stable over-curent (inkluż il-kurrent armoniku) inqas 1.3 In.
5.B'vultaġġ stand: bejn terminali 2.15, vultaġġ ratat ħin għal 10 sekondi, bejn terminali u kontenitur 42kV għal 10 sekondi.
Karatteristiċi tekniċi ewlenin:
1.Vultaġġ nominali: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, jekk jogħġbok indikat fl-ordni jekk trid il-kapaċità speċjali l-oħra.
Kapaċità 2.Rated: 33 ~ 334kvar jekk jogħġbok indikat fl-ordni jekk trid il-kapaċità speċjali l-oħra.
3.Tolleranza tal-kapaċità: -5 ~ 15%.
4.Loss anġlu valur tanġenzjali: film & papaer medju tg θ≦0.08%, film medju tg θ≦0.05%.
5.Withstand vultaġġ: li jistgħu jaffordjaw AC2.15 jew DC4.3 darbiet ratata vultaġġ bejn il-kapaċità pales, aħħar madwar 10s mingħajr waqfa jew flash, BIL: 6kV(30kV), 10kV(42Kv).
6.Kwittanza ħielsa: għandha r-reżistenza ta 'ġewwa, 10min wara li taqta' l-provvista tal-enerġija, il-vultaġġ residwu se jnaqqas għal 75V minn √2 Un.
7.Max. Kurrent: taħdem bla xkiel taħt il-vultaġġ nominali ta '1.3 ħin, vultaġġ żejjed, tolleranza pożittiva tal-kapaċità u mewġa armonika li ma tistax taqbeż 1 min kull 24 siegħa.
8.Max.Current: taħdem bla xkiel taħt il-vultaġġ nominali ta '1.3 ħin, vultaġġ żejjed, tolleranza pożittiva tal-kapaċità u mewġa armonika li ma tistax 1.43 kurrent nominali ħin.
9.Standard: GB/T 112024.1-2001, IEC6087:1997.
Kondensatur tal-Enerġija tal-Fażi separata
Mudell BAM | Vultaġġ Rated (kV) | Output Rated (kVAr) | Kapaċità Rated (uF) | Kurrent Rated In(A) |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
6.35-30-1W | 6.35 | 30 | 2.368 | 4.724 |
6.35-50-1W | 6.35 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | Erbgha u ghoxrin | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
6.35-50-1W | 6.35 | 50 | 3.95 | 7.87 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
3.81-50-1W | 3.81 | 50 | 10.96 | 13.12 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
6.93-100-1W | 6.93 | 100 | 6.63 | 14.4 |
6.93-150-1W | 6.93 | 150 | 9.95 | 21.7 |
6.93-200-1W | 6.93 | 200 | 13.3 | 28.9 |
6.93-300-1W | 6.93 | 300 | 19.9 | 43.3 |
6.93-334-1W | 6.93 | 334 | 22.1 | 48.2 |
6.93-400-1W | 6.93 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | Erbgha u ghoxrin | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | tnejn u ghoxrin | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |